close menu
Bookswagon-24x7 online bookstore
close menu
My Account
Methods of Analysis by the U.S. Geological Survey: Usgs Open-File Report 2000-170(English)

Methods of Analysis by the U.S. Geological Survey: Usgs Open-File Report 2000-170(English)

          
5
4
3
2
1

Out of Stock


Premium quality
Premium quality
Bookswagon upholds the quality by delivering untarnished books. Quality, services and satisfaction are everything for us!
Easy Return
Easy return
Not satisfied with this product! Keep it in original condition and packaging to avail easy return policy.
Certified product
Certified product
First impression is the last impression! Address the book’s certification page, ISBN, publisher’s name, copyright page and print quality.
Secure Checkout
Secure checkout
Security at its finest! Login, browse, purchase and pay, every step is safe and secured.
Money back guarantee
Money-back guarantee:
It’s all about customers! For any kind of bad experience with the product, get your actual amount back after returning the product.
On time delivery
On-time delivery
At your doorstep on time! Get this book delivered without any delay.
Notify me when this book is in stock
Add to Wishlist

About the Book

The National Water Quality Laboratory (NWQL) determined ammonium plus organic nitrogen (Kjeldahl nitrogen) by using semiautomated, block digester methods for filtered and whole-water samples from 1986 until October 1, 1991. During that time, phosphorus was determined by a persulfate digestion method. In 1991, projected increases in demand for both tests by the U.S. Geological Survey's National Water-Quality Assessment Program led the NWQL to develop and validate methods for determining both analytes in a common digest. This report describes a rapid and accurate method to determine Kjeldahl nitrogen. The batch, high-temperature (block digester), Hg (II)-catalyzed digestion step used in the new methods I-2515-91/4515-91 is similar to U.S. Geological Survey methods I-2552-85/4552-85 and U.S. Environmental Protection Agency method 351.2 except that sample and reagent volumes are halved. Prepared digests are desolvated at 220 degrees Celsius (oC) and digested at 370oC in separate block digesters set at these temperatures, rather than in a single, temperatureprogrammed block digester. This approach permits 40 calibrants, reference materials, and samples to be digested and resolvated in about an hour. Ammonium ions originally present in samples, along with those released during the digestion step, are determined photometrically by an automated, salicylatehypochlorite Berthelot reaction procedure at a rate of 90 tests per hour. About 100 microliters of digest are required per determination. The upper concentration level is 10 milligrams per liter (mg/L) with a method detection level of 0.05 mg/L. Repeatability for a sample containing about 4.1 mg/L of Kjeldahl nitrogen in a high suspended-solids matrix is 3.1 percent. Between-day precision for the same sample is 4.8 percent. A gas diffusion cell in the air-segmented continuous flow analyzer eliminates particulates and ions that otherwise would interfere in the photometric finish. A singlechannel analyzer can process the resolvated digests from two pairs of block digesters each hour. Statistical analysis of paired data for about 1,500 samples determined by U.S. Geological Survey methods I-2552-85/4552- 85 and I-2515-91/4515-91 during method validation revealed a median concentration difference between the former and the latter methods of about 0.1 mg-N/L. This result was expected because digestion blank concentrations (nearly equal to 0.1 mg/L) were not subtracted from concentrations reported by methods I-2552-85/4552-85. A 10-year record of National Water Quality Laboratory Kjeldahl nitrogen blind blank concentration data also supports a step-change decrease in Kjeldahl nitrogen concentrations of about 0.1 mg/L after methods I-2552-85/4552-85 were replaced by methods I-2515-91/4515-91 on October 1, 1991. Somewhat larger concentration differences between the two methods were observed for a subset of about 350 samples with nitrate plus nitrite concentrations greater than 1 mg-N/L.


Best Seller

| | See All

Product Details
  • ISBN-13: 9781288850112
  • Publisher: Bibliogov
  • Publisher Imprint: Bibliogov
  • Height: 246 mm
  • No of Pages: 40
  • Series Title: English
  • Sub Title: Usgs Open-File Report 2000-170
  • Width: 189 mm
  • ISBN-10: 1288850115
  • Publisher Date: 01 Mar 2013
  • Binding: Paperback
  • Language: English
  • Returnable: N
  • Spine Width: 2 mm
  • Weight: 91 gr


Similar Products

How would you rate your experience shopping for books on Bookswagon?

Add Photo
Add Photo

Customer Reviews

REVIEWS           
Be The First to Review
Methods of Analysis by the U.S. Geological Survey: Usgs Open-File Report 2000-170(English)
Bibliogov -
Methods of Analysis by the U.S. Geological Survey: Usgs Open-File Report 2000-170(English)
Writing guidlines
We want to publish your review, so please:
  • keep your review on the product. Review's that defame author's character will be rejected.
  • Keep your review focused on the product.
  • Avoid writing about customer service. contact us instead if you have issue requiring immediate attention.
  • Refrain from mentioning competitors or the specific price you paid for the product.
  • Do not include any personally identifiable information, such as full names.

Methods of Analysis by the U.S. Geological Survey: Usgs Open-File Report 2000-170(English)

Required fields are marked with *

Review Title*
Review
    Add Photo Add up to 6 photos
    Would you recommend this product to a friend?
    Tag this Book
    Read more
    Does your review contain spoilers?
    What type of reader best describes you?
    I agree to the terms & conditions
    You may receive emails regarding this submission. Any emails will include the ability to opt-out of future communications.

    CUSTOMER RATINGS AND REVIEWS AND QUESTIONS AND ANSWERS TERMS OF USE

    These Terms of Use govern your conduct associated with the Customer Ratings and Reviews and/or Questions and Answers service offered by Bookswagon (the "CRR Service").


    By submitting any content to Bookswagon, you guarantee that:
    • You are the sole author and owner of the intellectual property rights in the content;
    • All "moral rights" that you may have in such content have been voluntarily waived by you;
    • All content that you post is accurate;
    • You are at least 13 years old;
    • Use of the content you supply does not violate these Terms of Use and will not cause injury to any person or entity.
    You further agree that you may not submit any content:
    • That is known by you to be false, inaccurate or misleading;
    • That infringes any third party's copyright, patent, trademark, trade secret or other proprietary rights or rights of publicity or privacy;
    • That violates any law, statute, ordinance or regulation (including, but not limited to, those governing, consumer protection, unfair competition, anti-discrimination or false advertising);
    • That is, or may reasonably be considered to be, defamatory, libelous, hateful, racially or religiously biased or offensive, unlawfully threatening or unlawfully harassing to any individual, partnership or corporation;
    • For which you were compensated or granted any consideration by any unapproved third party;
    • That includes any information that references other websites, addresses, email addresses, contact information or phone numbers;
    • That contains any computer viruses, worms or other potentially damaging computer programs or files.
    You agree to indemnify and hold Bookswagon (and its officers, directors, agents, subsidiaries, joint ventures, employees and third-party service providers, including but not limited to Bazaarvoice, Inc.), harmless from all claims, demands, and damages (actual and consequential) of every kind and nature, known and unknown including reasonable attorneys' fees, arising out of a breach of your representations and warranties set forth above, or your violation of any law or the rights of a third party.


    For any content that you submit, you grant Bookswagon a perpetual, irrevocable, royalty-free, transferable right and license to use, copy, modify, delete in its entirety, adapt, publish, translate, create derivative works from and/or sell, transfer, and/or distribute such content and/or incorporate such content into any form, medium or technology throughout the world without compensation to you. Additionally,  Bookswagon may transfer or share any personal information that you submit with its third-party service providers, including but not limited to Bazaarvoice, Inc. in accordance with  Privacy Policy


    All content that you submit may be used at Bookswagon's sole discretion. Bookswagon reserves the right to change, condense, withhold publication, remove or delete any content on Bookswagon's website that Bookswagon deems, in its sole discretion, to violate the content guidelines or any other provision of these Terms of Use.  Bookswagon does not guarantee that you will have any recourse through Bookswagon to edit or delete any content you have submitted. Ratings and written comments are generally posted within two to four business days. However, Bookswagon reserves the right to remove or to refuse to post any submission to the extent authorized by law. You acknowledge that you, not Bookswagon, are responsible for the contents of your submission. None of the content that you submit shall be subject to any obligation of confidence on the part of Bookswagon, its agents, subsidiaries, affiliates, partners or third party service providers (including but not limited to Bazaarvoice, Inc.)and their respective directors, officers and employees.

    Accept

    New Arrivals

    | | See All


    Inspired by your browsing history


    Your review has been submitted!

    You've already reviewed this product!
    ASK VIDYA