Home > Mathematics and Science Textbooks > Chemistry > Analytical chemistry > Chromatography > Modern HPLC for Practicing Scientists
14%
Modern HPLC for Practicing Scientists

Modern HPLC for Practicing Scientists

          
5
4
3
2
1

Out of Stock


Premium quality
Premium quality
Bookswagon upholds the quality by delivering untarnished books. Quality, services and satisfaction are everything for us!
Easy Return
Easy return
Not satisfied with this product! Keep it in original condition and packaging to avail easy return policy.
Certified product
Certified product
First impression is the last impression! Address the book’s certification page, ISBN, publisher’s name, copyright page and print quality.
Secure Checkout
Secure checkout
Security at its finest! Login, browse, purchase and pay, every step is safe and secured.
Money back guarantee
Money-back guarantee:
It’s all about customers! For any kind of bad experience with the product, get your actual amount back after returning the product.
On time delivery
On-time delivery
At your doorstep on time! Get this book delivered without any delay.
Notify me when this book is in stock
Add to Wishlist

About the Book

A comprehesive yet concise guide to Modern HPLC Written for practitioners by a practitioner, Modern HPLC for Practicing Scientists is a concise text which presents the most important High-Performance Liquid Chromatography (HPLC) fundamentals, applications, and developments. It describes basic theory and terminology for the novice, and reviews relevant concepts, best practices, and modern trends for the experienced practitioner. Moreover, the book serves well as an updated reference guide for busy laboratory analysts and researchers. Topics covered include: HPLC operation Method development Maintenance and troubleshooting Modern trends in HPLC such as quick-turnaround and "greener" methods Regulatory aspects While broad in scope, this book focuses particularly on reversed-phase HPLC, the most common separation mode, and on applications for the pharmaceutical industry, the largest user segment. Accessible to both novice and intermedate HPLC users, information is delivered in a straightforward manner illustrated with an abundance of diagrams, chromatograms, tables, and case studies, and supported with selected key references and Web resources. With intuitive explanations and clear figures, Modern HPLC for Practicing Scientists is an essential resource for practitioners of all levels who need to understand and utilize this versatile analytical technology.

Table of Contents:
Preface. 1 Introduction. 1.1 Introduction. 1.1.1 Scope. 1.1.2 What Is HPLC? 1.1.3 A Brief History. 1.1.4 Advantages and Limitations. 1.2 Modes of HPLC. 1.2.1 Normal-Phase Chromatography (NPC). 1.2.2 Reversed-Phase Chromatography (RPC). 1.2.3 Ion-Exchange Chromatography (IEC). 1.2.4 Size-Exclusion Chromatography (SEC). 1.2.5 Other Separation Modes. 1.3 Some Common-Sense Corollaries. 1.4 How to Get More Information. 1.5 Summary. 1.6 References. 2 Basic Terms and Concepts. 2.1 Scope. 2.2 Basic Terms and Concepts. 2.2.1 Retention Time (tR),Void Time (tM), Peak Height (h), and Peak Width (wb). 2.2.2 Retention Volume (VR),Void Volume (VM), and Peak Volume. 2.2.3 Retention Factor (k). 2.2.4 Separation Factor (α). 2.2.5 Column Efficiency and Plate Number (N). 2.2.6 Peak Volume. 2.2.7 Height Equivalent to a Theoretical Plate or Plate Height (HETP or H). 2.2.8 Resolution (Rs). 2.2.9 Peak Symmetry: Asymetry Factor (As) and Tailing Factor (Tf). 2.3 Mobile Phase. 2.3.1 General Requirements. 2.3.2 Solvent Strength and Selectivity. 2.3.3 Buffers. 2.3.4 Acidic Mobile Phases. 2.3.5 Ion-Pairing Additives. 2.3.6 High pH Mobile Phase. 2.3.7 Other Operating Parameters: Flow Rate (F) and Column Temperature (T). 2.4 The Resolution Equation. 2.5 The Van Deemter Equation. 2.6 Isocratic vs. Gradient Analysis. 2.6.1 Peak Capacity (n). 2.6.2 Key Gradient Parameters (Initial and Final Solvent Strength, Gradient Time [tG], and Flow Rate). 2.6.3 The 0.25tG Rule:When Is Isocratic Analysis More Appropriate? 2.7 Concept of Orthogonality. 2.8 Sample Capacity. 2.9 Glossary of HPLC Terms. 2.10 Summary and Conclusion. 2.11 References. 3 HPLC Columns and Trends. 3.1 Scope. 3.2 General Column Description and Characteristics. 3.2.1 Column Hardware—Standard vs. Cartridge Format. 3.3 Column Types. 3.3.1 Types Based on Chromatographic Modes. 3.3.2 Types Based on Dimensions. 3.3.3 Column Length (L). 3.4 Column Packing Characteristics. 3.4.1 Support Type. 3.4.2 Particle Size (dp). 3.4.3 Surface Area and Pore Size (dpore). 3.4.4 Bonding Chemistries. 3.4.5 Some General Guidelines for Bonded Phase Selection. 3.5 Modern HPLC Column Trends. 3.5.1 High-Purity Silica. 3.5.2 Hybrid Particles. 3.5.3 Novel Bonding Chemistries. 3.5.4 Fast LC. 3.5.5 Micro LC. 3.5.6 Monoliths. 3.6 Guard Columns. 3.7 Specialty Columns. 3.7.1 Bioseparation Columns. 3.7.2 Chiral Columns. 3.7.3 Application-Specific Columns. 3.8 Column Selection Guides. 3.9 Summary. 3.10 References. 3.11 Internet Resources. 4 HPLC Instrumentation and Trends. 4.1 Introduction. 4.1.1 Scope. 4.1.2 HPLC Systems and Modules. 4.2 HPLC Solvent Delivery Systems. 4.2.1 High-Pressure and Low-Pressure Mixing Designs in Multisolvent Pumps. 4.2.2 System Dwell Volume. 4.2.3 Trends. 4.3 Injectors and Autosamplers. 4.3.1 Operating Principles of Autosamplers. 4.3.2 Performance Characteristics and Trends. 4.4 Detectors. 4.5 UV/VIS Absorbance Detectors. 4.5.1 Operating Principles. 4.5.2 Performance Characteristics. 4.5.3 Trends in Absorbance Detectors. 4.6 Photodiode Array Detectors. 4.6.1 Operating Principles. 4.6.2 Trends in PDA Detectors. 4.7 Other Detectors. 4.7.1 Fluorescence Detector (FLD). 4.7.2 Refractive Index Detector (RID). 4.7.3 Evaporative Light Scattering Detector (ELSD). 4.7.4 Corona-Charged Aerosol Detector (CAD). 4.7.5 Chemiluminescence Nitrogen Detector (CLND). 4.7.6 Electrochemical Detector (ECD). 4.7.7 Conductivity Detector. 4.7.8 Radiometric Detector. 4.8 Hyphenated and Specialized Systems. 4.8.1 LC/MS, LC/MS/MS. 4.8.2 LC/NMR. 4.8.3 Other Hyphenated Systems. 4.8.4 Prep LC and Bio-Purification Systems. 4.8.5 Proteomics Systems: Capillary LC and Multi-Dimensional LC. 4.8.6 High-Throughput Screening (HTS) and Parallel Analysis Systems. 4.8.7 Ultra-High-Pressure Liquid Chromatography. 4.8.8 Lab-on-a-Chip. 4.8.9 Specialized Applications Systems. 4.9 HPLC Accessories and Data Handling Systems. 4.9.1 Solvent Degasser. 4.9.2 Column Oven. 4.9.3 Column Selector Valve. 4.9.4 Data Handling and HPLC Controllers. 4.10 Instrumental Bandwidth (IBW). 4.11 Trends in HPLC Equipment. 4.12 Manufacturers and Equipment Selection. 4.13 Summary. 4.14 References. 4.15 Internet Resources. 5 HPLC Operation Guide. 5.1 Scope. 5.2 Safety and Environmental Concerns. 5.2.1 Safety Concerns. 5.2.2 Environmental Concerns. 5.3 Mobile Phase Preparation. 5.3.1 Mobile Phase Premixing. 5.3.2 Buffers. 5.3.3 Filtration. 5.3.4 Degassing. 5.4 Best Practices in HPLC System Operation. 5.4.1 Pump Operation. 5.4.2 HPLC Column Use, Connection, and Maintenance. 5.4.2.1 Column Use. 5.4.2.2 Column Precautions. 5.4.2.3 Column Connection. 5.4.2.4 Column Maintenance and Regeneration. 5.4.3 Autosampler Operation. 5.4.4 Detector Operation. 5.4.5 System Shutdown. 5.4.6 Guidelines for Increasing HPLC Precision. 5.4.6.1 Guidelines for Improving Retention Time Precision. 5.4.6.2 Guidelines for Improving Peak Area Precision. 5.5 From Chromatograms to Reports. 5.5.1 Qualitative Analysis Strategies. 5.5.2 Quantitation Analysis Strategies. 5.6 Summary of HPLC Operation. 5.7 Guides on Performing Trace Analysis. 5.8 Summary. 5.9 References. 6 Pharmaceutical Analysis. 6.1 Introduction. 6.1.1 Scope. 6.1.2 Overview: From Drug Discovery to Quality Control. 6.1.3 Sample Preparation Perspectives in Drug Product Analysis. 6.1.4 High-Throughput LC/MS in Drug Discovery Support. 6.2 Identification. 6.3 Assays. 6.3.1 Drug Substances. 6.3.2 Drug Products. 6.3.3 Content Uniformity. 6.3.4 Products with Multiple APIs and Natural Products. 6.3.5 Assay of Preservatives. 6.4 Impurity Testing. 6.4.1 Trends in Impurity Testing. 6.5 Dissolution Testing. 6.6 Cleaning Validation. 6.7 Bioanalytical Testing. 6.8 Chiral Analysis. 6.9 Case Study: HPLC Methods in Early Development. 6.10 Summary. 6.11 References. 7 Food, Environmental, Chemical, and Life Sciences Applications. 7.1 Introduction. 7.1.1 Scope. 7.2 Food Applications. 7.2.1 Natural Food Components. 7.2.1.1 Sugars. 7.2.1.2 Fats, Oils, and Triglycerides. 7.2.1.3 Free Fatty Acids and Organic Acids. 7.2.1.4 Proteins and Amino Acids. 7.2.2 Food Additives. 7.2.2.1 Flavors: A Case Study on HPLC Analysis of Capsaicins. 7.2.3 Contaminants. 7.2.3.1 Mycotoxins. 7.2.3.2 Antimicrobial Additives. 7.2.3.3 Pesticide Residues. 7.3 Environmental Applications. 7.3.1 Listing of Important U.S. EPA HPLC Methods. 7.3.2 Pesticides Analysis. 7.3.2.1 Carbamates and Glyphosate. 7.3.3 Polynuclear Aromatic Hydrocarbons (PAH). 7.3.3.1 Case Study: Quick Turnaround Analysis of PAHs by HPLC in Multimedia Samples. 7.4 Chemical, GPC and Plastics Applications. 7.4.1 Gel-Permeation Chromatography (GPC) and Analysis of Plastics Additives. 7.5 Ion Chromatography. 7.6 Life Sciences Applications. 7.6.1 Proteins, Peptides, and Amino Acids. 7.6.2 Bases, Nucleosides, Nucleotides, Oligonucleotides, Nucleic Acids, and PCR Products. 7.7 Summary. 7.8 References. 8 HPLC Method Development. 8.1 Introduction. 8.1.1 Scope. 8.1.2 Considerations Before Method Development. 8.1.3 Strategy for Method Development. 8.1.4 HPLC Method Development Trends in Pharmaceutical Analysis. 8.2 Defining Method Types and Goals. 8.2.1 Method Goals. 8.3 Gathering Sample and Analyte Information. 8.3.1 Defining Sample Preparation Requirements. 8.4 Initial HPLC Method Development. 8.4.1 Initial Detector Selection. 8.4.2 Selection of Chromatographic Mode. 8.4.3 Initial Selection of HPLC Column. 8.4.4 Generating a First Chromatogram. 8.4.4.1 Case Study: Initial Method Development Using a Broad Gradient and Mobile Phase Selection. 8.5 Method Fine-Tuning. 8.5.1 Mobile Phase Parameters (%B, Buffer, pH, Solvent Type). 8.5.2 Operating Parameters (F, T, φ, tG). 8.5.3 Column Parameters (Bonded Phase Type, L, dp, dc). 8.5.4 Detector Setting and Sample Amount. 8.5.5 Summary of Method Development Steps. 8.6 Phase-Appropriate Method Development. 8.7 Method Development Software Tools. 8.8 Case Studies. 8.8.1 Composite Assay Method for a Neutral Drug Substance. 8.8.2 Composite Drug Substance Method for a Basic Drug Substance. 8.8.3 Impurity Method for a Drug Product with Two APIs. 8.9 Summary and Conclusions. 8.10 References. 9 Regulatory Aspects of HPLC Analysis: HPLC System and Method Validation. 9.1 Introduction. 9.1.1 Scope. 9.1.2 The Regulatory Environment. 9.2 HPLC System Qualification. 9.2.1 Design Qualification (DQ). 9.2.2 Installation Qualification (IQ). 9.2.3 Operational Qualification (OQ). 9.2.4 Performance Qualification (PQ). 9.2.5 Documentation. 9.2.6 System Calibration. 9.3 Method Validation. 9.3.1 Validation Parameters. 9.4 System Suitability Testing (SST). 9.5 Case Study on Method Validation. 9.6 Cost-Effective Regulatory Compliance. 9.7 Summary and Conclusions. 9.8 References. 9.9 Internet Resources. 10 HPLC Maintenance and Troubleshooting Guide. 10.1 Scope. 10.2 HPLC System Maintenance. 10.2.1 LC Pump. 10.2.2 UV/Vis Detectors. 10.2.3 Injector and Autosampler. 10.3 HPLC Troubleshooting. 10.3.1 General Problem Diagnostic and Troubleshooting Guide. 10.3.2 Common HPLC Problems. 10.3.2.1 Pressure Problems and Causes. 10.3.2.2 Baseline Problems (Chromatogram). 10.3.2.3 Peak Problems (Chromatogram). 10.3.2.4 Data Performance Problems. 10.4 Case Studies. 10.4.1 Case Study 1: Reducing Baseline Shift and Noise for Gradient Analysis. 10.4.2 Case Study 2: Poor Peak Area Precision Encountered During HPLC System Calibration. 10.4.3 Case Study 3: Poor Assay Accuracy Data, an Out-of- Specification Investigation. 10.4.4 Case Study 4: Equipment Malfunctioning. 10.5 Summary and Conclusion. 10.6 References. 10.7 Internet Resources. 11 Modern Trends in HPLC. 11.1 Columns: Shorter and Narrower Packed with Small Particles. 11.2 Column Packing: Novel Bonded Phases. 11.3 Pumps. 11.4 Autosamplers. 11.5 Detectors. 11.6 HPLC Systems. 11.6.1 Low-Dispersion Instruments. 11.6.2 Ultra-High-Pressure LC. 11.6.3 Multi-Dimensional LC. 11.6.4 Parallel Analysis. 11.7 Lab-on-a-Chip. 11.8 Data Handling. 11.9 Regulatory Compliance. 11.10 Greener HPLC Methods. 11.11 Summary and Conclusions. 11.12 References. Index.


Best Sellers


Product Details
  • ISBN-13: 9780471727897
  • Publisher: John Wiley & Sons Inc
  • Publisher Imprint: Wiley-Interscience
  • Depth: 1
  • Language: English
  • Returnable: N
  • Spine Width: 20 mm
  • Width: 152 mm
  • ISBN-10: 047172789X
  • Publisher Date: 11 Jul 2006
  • Binding: Paperback
  • Height: 231 mm
  • No of Pages: 304
  • Series Title: English
  • Weight: 431 gr


Similar Products

How would you rate your experience shopping for books on Bookswagon?

Add Photo
Add Photo

Customer Reviews

REVIEWS           
Click Here To Be The First to Review this Product
Modern HPLC for Practicing Scientists
John Wiley & Sons Inc -
Modern HPLC for Practicing Scientists
Writing guidlines
We want to publish your review, so please:
  • keep your review on the product. Review's that defame author's character will be rejected.
  • Keep your review focused on the product.
  • Avoid writing about customer service. contact us instead if you have issue requiring immediate attention.
  • Refrain from mentioning competitors or the specific price you paid for the product.
  • Do not include any personally identifiable information, such as full names.

Modern HPLC for Practicing Scientists

Required fields are marked with *

Review Title*
Review
    Add Photo Add up to 6 photos
    Would you recommend this product to a friend?
    Tag this Book
    Read more
    Does your review contain spoilers?
    What type of reader best describes you?
    I agree to the terms & conditions
    You may receive emails regarding this submission. Any emails will include the ability to opt-out of future communications.

    CUSTOMER RATINGS AND REVIEWS AND QUESTIONS AND ANSWERS TERMS OF USE

    These Terms of Use govern your conduct associated with the Customer Ratings and Reviews and/or Questions and Answers service offered by Bookswagon (the "CRR Service").


    By submitting any content to Bookswagon, you guarantee that:
    • You are the sole author and owner of the intellectual property rights in the content;
    • All "moral rights" that you may have in such content have been voluntarily waived by you;
    • All content that you post is accurate;
    • You are at least 13 years old;
    • Use of the content you supply does not violate these Terms of Use and will not cause injury to any person or entity.
    You further agree that you may not submit any content:
    • That is known by you to be false, inaccurate or misleading;
    • That infringes any third party's copyright, patent, trademark, trade secret or other proprietary rights or rights of publicity or privacy;
    • That violates any law, statute, ordinance or regulation (including, but not limited to, those governing, consumer protection, unfair competition, anti-discrimination or false advertising);
    • That is, or may reasonably be considered to be, defamatory, libelous, hateful, racially or religiously biased or offensive, unlawfully threatening or unlawfully harassing to any individual, partnership or corporation;
    • For which you were compensated or granted any consideration by any unapproved third party;
    • That includes any information that references other websites, addresses, email addresses, contact information or phone numbers;
    • That contains any computer viruses, worms or other potentially damaging computer programs or files.
    You agree to indemnify and hold Bookswagon (and its officers, directors, agents, subsidiaries, joint ventures, employees and third-party service providers, including but not limited to Bazaarvoice, Inc.), harmless from all claims, demands, and damages (actual and consequential) of every kind and nature, known and unknown including reasonable attorneys' fees, arising out of a breach of your representations and warranties set forth above, or your violation of any law or the rights of a third party.


    For any content that you submit, you grant Bookswagon a perpetual, irrevocable, royalty-free, transferable right and license to use, copy, modify, delete in its entirety, adapt, publish, translate, create derivative works from and/or sell, transfer, and/or distribute such content and/or incorporate such content into any form, medium or technology throughout the world without compensation to you. Additionally,  Bookswagon may transfer or share any personal information that you submit with its third-party service providers, including but not limited to Bazaarvoice, Inc. in accordance with  Privacy Policy


    All content that you submit may be used at Bookswagon's sole discretion. Bookswagon reserves the right to change, condense, withhold publication, remove or delete any content on Bookswagon's website that Bookswagon deems, in its sole discretion, to violate the content guidelines or any other provision of these Terms of Use.  Bookswagon does not guarantee that you will have any recourse through Bookswagon to edit or delete any content you have submitted. Ratings and written comments are generally posted within two to four business days. However, Bookswagon reserves the right to remove or to refuse to post any submission to the extent authorized by law. You acknowledge that you, not Bookswagon, are responsible for the contents of your submission. None of the content that you submit shall be subject to any obligation of confidence on the part of Bookswagon, its agents, subsidiaries, affiliates, partners or third party service providers (including but not limited to Bazaarvoice, Inc.)and their respective directors, officers and employees.

    Accept

    New Arrivals


    Inspired by your browsing history


    Your review has been submitted!

    You've already reviewed this product!
    ASK VIDYA